SPL Splicing SPL-04 Step 4 of 13

Mid-Span Access and Expressing Tubes

Open a cable at mid-span and reach only the fibers you need, without disturbing the express fibers that stay in service.

ChecklistOn the Map

Crew

  • Lead Splicer
  • Splicer Helper

Hazards

  • Cutting a Live Express Fiber
  • Induced or Fault Voltage on Cut Armor
  • Cuts from Sheath Tools
  • Glass Fiber Shards

Purpose

Reach only the fibers you need in a cable that passes through the closure, without disturbing the express fibers that stay whole. Express fibers may already carry live customers. One wrong cut can take down a feeder.

When to Do It

Roles

  • Lead splicer: makes the window cut, opens the assigned tubes and cuts only the assigned fibers.
  • Splicer helper: supports the express loop, reads the matrix aloud and confirms each fiber id before a cut.

Equipment and Materials

  • Mid-sheath window cutter or sheath slitting tool.
  • Mid-span access tool sized for the buffer tubes.
  • Closure express basket and the closure’s tube ties.
  • Visual fault locator (VFL), for fiber checks where the owner allows.
  • The current splice matrix.

Safety

Procedure

  1. Make the mid-sheath window cut per the closure instructions.
    • Use the window length the closure model requires: per manufacturer instructions.
    • Set the tool depth so it opens the jacket without touching the tubes.
    • Secure the strength members at both ends of the window in the closure’s clamps.
    • On armored cable, bond the armor on both sides of the window to the closure bond bar, so armor continuity and grounding are kept (owner bonding standard; NESC).
  2. Route the uncut express tubes through the express basket.
    • Lay them in a loose loop that keeps the bend radius: per manufacturer instructions.
    • Do not twist or pinch the tubes under the basket cover, so express fibers do not pick up bend loss.
  3. Open only the tubes being accessed.
    • Identify each tube by color with the TIA-598 sequence and check it against the matrix.
    • Open the tube with a mid-span access tool, not a knife, so the fibers inside are not scored.
  4. Identify the fibers assigned to splice.
    • Read each fiber color and count against the matrix.
    • Have the helper read the matrix aloud while you point to each fiber.
  5. Cut only the fibers assigned to splice in the matrix.
    • Never cut an express fiber.
    • Leave the cut fibers long enough to reach their tray.
  6. Route the cut fibers to their trays and leave the express fibers in their tube or loop.

Hold Points

Records to Keep

  • Photo of the express basket with the express loop in place.
  • Photo of the armor bonds on both sides of the window, on armored cable.
  • Matrix marked with the fibers cut and the fibers expressed.
  • Name of the owner contact if live traffic was coordinated.

Common Mistakes

  • Cutting a live express fiber. This is the costliest splicing mistake. Verify every fiber against the matrix before you cut.
  • Kinked express tubes. A tight loop adds loss on fibers that already work. Keep a loose loop within bend radius.
  • Unbonded armor at the window. Cutting the window splits the armor in two. Bond both sides to the closure bond bar, or one side floats.
  • Overfilled baskets. Tubes crushed under the basket cover pick up macrobends. Use the closure’s capacity limits.

Standards and References

  • Telcordia GR-771
  • ANSI/TIA-598
  • NESC (IEEE C2) for bonding and grounding.
  • Owner bonding and grounding standard.
  • Closure manufacturer’s instructions for mid-span entry and express storage.
  • Owner network operations procedures for working near live service.

On the Map

  • Fiber Color Locator: confirm which tube and fiber colors match the fiber numbers in the matrix.

SPL-04 · Field Checklist

Checklist

0/8items ticked

Tick each procedure step and hold point as the crew completes it. Ticks stay on this device only. They are a personal aid, not a hold-point release or a project record; follow the owner’s sign-off process.

Procedure
Hold Points

OSP Map · Handhole Detail

On the Map

Open the map

Report an Issue

Spotted something wrong or out of date? Emailfeedback@fahmy.iowith the step and version (SPL-04, v1.0.0) and what you saw in the field.

FAHMY is a reference, not a substitute for owner specifications, the authority having jurisdiction, manufacturer instructions, training or qualified supervision. Follow your employer's safety program and all applicable laws.